The aim of the current bilateral project between CEA Cadarache and JSI is to improve the accuracy of the online thermal power monitoring at the JSI TRIGA reactor. Simultaneously, a new wide range multichannel acquisition system for fission chambers, recently developed by CEA, is tested. In the paper, calculational and experimental power calibration methods are described. The focus is on use of multiple detectors in combination with pre-calculated and pre-measured control-rod-position-dependent correction factors to improve the reactor power reading. The system will be implemented and tested at the JSI TRIGA reactor in 2014.
COBISS.SI-ID: 28005159
A complete evaluation of the experimental uncertainties of the KRITZ-2 series of critical and relative fission rate experiments was performed within the International Reactor Physics Experiment Evaluation Project. The uncertainties in the benchmark model keff are mainly due to uranium enrichment, plutonium content [mixed oxide (MOX) fuel], pitch, and boron isotopic composition. The largest contribution to the uncertainty in the benchmark model keff is from the uncertainty in the bias due to the homogenization of the particulate MOX fuel. In addition, uncertainties due to nuclear data libraries are presented. The keff's calculated with various nuclear data libraries systematically underpredict the benchmark model keff by one to three times the standard experimental uncertainties. When taking into account uncertainties in nuclear data estimated using SCALE-6.0 and JENDL-4.0m covariances, the benchmark and calculated keff's agree within 1% of the total%experimental plus calculational%uncertainties. In contrast to the criticality benchmark data, the calculated relative fission rates agree very well with the experimental ones, especially when eliminating systematic errors due to normalization.
COBISS.SI-ID: 28168999
We generated a preliminary set of resonance parameters for 182,183,184,186W in the neutron energy range of thermal up to several keV. The evaluation methodology uses the Reich-Moore approximation to fit with the R-matrix code SAMMY, the high-resolution measurements performed in 2010 and 2012 at the Geel linear accelerator facility. For 183W, the transmission data and capture cross sections calculated with the set of resonance parameters are compared with the experimental values, and some of the average properties of the resonance parameters are discussed. In the analyzed energy range, this work almost doubles the existing resolved resonance evaluations in the ENDF/B-VII.1 library. A preliminary analysis of the performance of the calculated cross sections based on Lead slowing-down benchmarks is presented and briefly discussed
COBISS.SI-ID: 27767079
Concurrent treatment with temozolomide and radiotherapy followed by maintenance temozolomide is the standard of care for patients with newly diagnosed glioblastoma. Bevacizumab, a humanized monoclonal antibody against vascular endothelial growth factor A, is currently approved for recurrent glioblastoma. Whether the addition of bevacizumab would improve survival among patients with newly diagnosed glioblastoma is not known.
COBISS.SI-ID: 28304167